Voltron-10KVA-Hybrid-Inverter(VT3500-10K-Pro)

0 Review(s)
in stock

QUICK OVERVIEW

MECHANICAL SPECIFICATIONS
Mounting :   Wall mount
Inverter dimensions (W*H*D):    587*414*211mm
Inverter weight (solar chg) KG:    60+2.5
Shipping dimensions(W*H*D):    750*520*310mm
Shipping weight (solar chg) KG:    62+2.5

OTHER
Operation   Temperature  Range:    0°C to 40°C
Storage   Temperature:     -15°C to 60°C
Audible   Noise:    60dB MAX
Display:    LED+LCD
Standard warranty:    1 year

919,999.00

Description

  • Power range 10KVA
  • 24V/48VDC input voltage
  • Powerful charge rate up to 65Amp
  • Inbuilt pure copper transformer
  • Pure sine wave output
  • LED+LCD display
  • MPPT solar charge controller 120A
  • MPPT efficiency max 98%
  • 50/60Hz automatic sensing
  • RS232 with free CD
  • Battery priority function
  • Automatically send signal to start generator
  • DC start & automatic self-diagnostic function
  • High efficiency design & “Power Saving Mode” to conserve energy

MODEL :   PV35-10K Pro
Default Battery System Voltage:    48VDC

INVERTER OUTPUT
Continuous output power :   10KVA/8.0KW
Surge rating (20ms):    24.0KW
Capable Of Starting Electric Motor:    4HP
Output waveform :   Pure sine wave/ same as input (bypass mode)
Inverter Efficiency(Peak) :   >88%
Line mode efficiency :   >95%
Power factor :   1.0
Nominal output voltage:  RMS    220V/230V/240VAC(+/-10% RMS)
Output frequency:    5OHz/60Hz +/-0.3 Hz
Short circuit protection:    Yes (1sec after fault)
Typical transfer time:    10ms(max) 10ms(max)

AC INPUT
Voltage:    230VAC
Selectable Voltage Range:    155~280VAC(For Personal Computers)
Frequency Range:    50HZ/60HZ (Auto sensing) 40~80Hz

BATTERY
Minimum start voltage :   20.OVDC/21.0VDC for24VDC mode (40.OVDC/42.0VDC for 48VDC mode)
Low battery alarm :   21.0VDC+/-0.3V for 24VDC mode (42.OVDC+/-0.6V  for 48VDC mode)
Low battery Cutoff :   20.0VDC+/-0.3V for 24VDC mode (40.OVDC+/-0.6V  for 48VDC mode)
High voltage alarm :   32.0VDC+/-0.3V for 24VDC mode (64.OVDC+/-0.6V  for 48VDC mode)
High battery voltage recover:    31.0VDC+/-0.3V for 24VDC mode (62.OVDC+/-0.6V  for 48VDC mode)
Idle consumption-search mode:    <25W when power saver on

CHARGER
Output voltage :   Depends on battery type
Charger AC input breaker rating:    40A
Max charge power rate:    1/3 Rating power
Overcharge protection S.D.:    31.4VDC for 24VDC mode (62.8VDC for 48VDC mode )
Maximum Charge Current:    70A

BTS
Continuous output power    Yes Variances in charging voltage & S.D. voltage base on the battery temperature  BYPASS & PROTECTION
Input voltage waveform :   Sine wave (grid or generator)
Nominal voltage:    220V/230V/240VAC
Max input AC voltage:    300VAC for 230VAC HV mode
Nominal input frequency:    50Hz or 60Hz
Overload protection (SMPS load):    Circuit breaker
Output short circuit protection:    Circuit breaker
Bypass breaker rating :   50A
Max bypass current        80Amp
Rated voltage:    24VDC/48VDC
PV open circuit voltage:    Operational max = 145VDC temperature corrected VOC

SOLAR CHARGER
Maximum PV Charge Current :   120A
DC Voltage:        48V
Maximum PV Array Power:    6400W
MPPT Range @ Operating Voltage:     64~145VDC
Maximum PV Array Open Circuit Voltage:    147VDC
Maximum Efficiency:    >98%
Standby Power Consumption:    <2W

Reviews

There are no reviews yet.

Be the first to review “Voltron-10KVA-Hybrid-Inverter(VT3500-10K-Pro)”

Please wait...

Subscribe to our newsletter

Subscribe to our mailing list to get the latest updates on products and offers.